Correct transportation and placement method of high and low temperature test chamber

1. Handling and transportation of high and low temperature test chambers 1. When carrying, lift the foot, do not grasp the force on the door handle, and can not drag on the ground;
2. The maximum tilt angle of the cabinet should not exceed 15 degrees, and it should not be inverted or horizontally placed. Otherwise, the compressor will be damaged or the refrigeration oil in the compressor will flow into the refrigeration pipeline, which will affect the refrigeration and easily cause the compressor to be unspring.
3. During the transportation process, it is necessary to prevent bumps and severe vibrations, and to prevent rain and water from immersing.

Second, the placement method 1. High and low temperature test chamber should be placed away from the heat source, not exposed to direct sunlight, because the work needs to exchange heat with the outside, not only through the condenser to the outside world, the higher the ambient temperature, the slower the heat dissipation Increase power consumption and poor cooling performance.
2. The compressor should be placed in a place with low humidity. Because the high and low temperature test chamber casing, condenser and compressor are all metal materials, if the humidity of the air is too high, these parts will rust and shorten the use of high and low temperature test chambers. life. At the same time, the humid and overheated environment will cause condensation on the surface of the test chamber and affect the performance of the machine.
3. It should be placed in a well-ventilated place. If the high and low temperature test chamber is full of debris, or the wall is too close, it will not affect the cooling effect.
4. Place on a flat, solid floor and keep the compressor level. This is not only for safety reasons, but also allows the compressor to work smoothly, reducing vibration and noise.
5. Do not place in places where the temperature is too low. Because the temperature is too low, the compressor is difficult to start.
6. Do not place in an environment that is flammable, explosive, or corrosive.

Article source: Beijing Yashilin Test Equipment Co., Ltd.

Test Tube Rack

Test Tube Rack,Tube Rack, Laboratory Test Tube Rack, Centrifuge Tube Rack; Plastic Tube Rack, PlasticTest Tube Rack

Test Tube Rack,Tube Rack, Laboratory Test Tube Rack,Centrifuge Tube Rack,Plastic Tube Rack

Luck Medical Consumables Co.,LIMITED , https://www.luckmedical.com

Posted on