Non-invasive blood glucose monitoring using near-infrared spectroscopy

Blood glucose monitors are used to measure the amount of glucose in a patient's blood, especially in patients with diabetes symptoms or a history of hyperglycemia or hypoglycemia. In general, blood glucose monitors help diabetics control the right insulin dose. The emergence of home blood glucose meters (non-clinical devices) has greatly improved the quality of life of patients. However, each time you use this monitor to measure, you not only need to collect finger blood, causing pain and inconvenience, but also use new test paper, which increases the cost of using the device.

To determine the most appropriate insulin dose requires frequent or continuous monitoring of blood glucose, but current blood glucose meters do not meet this requirement. Continuous monitors do exist, but need to be implanted subcutaneously, cause trauma after implantation, and be replaced weekly. There is also a non-invasive blood glucose monitor. This article describes an architecture that uses near-infrared (NIR) spectroscopy to determine blood glucose levels based on the transmission spectrum of the earlobe. Due to the use of various human parameters such as tissue thickness and oxygen saturation and calibration systems based on linear regression analysis, an accurate real-time architecture is recommended. An example of the full analog, digital, and mixed-signal functions of the Cypress programmable system-on-chip PSoC-5LP controller is also presented.

High blood sugar and low blood sugar

Hyperglycemia and hypoglycemia refer to physical conditions in which blood glucose levels are higher or lower than normal. Diabetes is a condition in which the body's pancreas stops secreting insulin that controls blood sugar levels. The cause of diabetes is not yet fully understood, but it is widely believed that diabetes may be caused by genetic factors and excessive dietary intake of sugar [1]. Once diagnosed with diabetes, blood glucose levels are constantly monitored to allow timely intake of medicinal insulin. Patients with hyperglycemia will exhibit persistent high blood glucose levels and need ongoing blood glucose monitoring [1]. Since current measuring devices monitor blood glucose levels by invasive methods, it is necessary to frequently extract blood samples from patients, sometimes leading to other complications such as bleeding, blood loss and allergies. Non-invasive technology can solve blood collection problems. This article will explore and implement a non-invasive blood glucose monitoring program.

Because of its high sensitivity, high selectivity, low cost and easy portability, NIR spectroscopy has chosen this technology [1]. At the same time, we chose a wavelength of 1550nm, which means that the signal-to-noise ratio (SNR) of the glucose signal is higher at this wavelength.

Working principle / system design

The near-infrared transmission spectroscopy technique was used to measure blood glucose on both sides of the earlobe, and a light source and a photodetector were placed on both sides of the earlobe. The amount of near-infrared light passing through the earlobe depends on the amount of blood sugar in the area. The earlobe was chosen for measurement because the earlobe had no bone tissue and was relatively thin [1]. At the same time, near-infrared (NIR) light is required to illuminate one side of the earlobe, while a receiver placed on the other side is used to receive the attenuated light, and then the attenuated optical signal is sampled and processed.

Two Thorlabs LEDs (LED 1550E) were selected as the light source [2]. Since conventional silicon photodiodes have limited spectral bandwidth and cannot be used to receive near-infrared light, other types of photodiodes must be used. In this case, we chose a high-sensitivity Marktech indium gallium arsenide photodiode with a wavelength of 1550 nm [3]. Connect the RC low-pass filter to the output of the photodiode to reduce high frequency noise. The cost of a light emitter and receiver having a wavelength of 1550 nm is relatively low compared to other wavelengths having the same or higher glucose responsiveness.

In addition to the amount of glucose in the blood, the transmittance of near-infrared light depends on the amount of blood in the light path. That is, at the same glucose level, a larger amount of blood leads to a lower transmittance, and vice versa. Therefore, it is necessary to adjust the value of glucose according to the amount of blood in the earlobe at the time of measurement. The amount of blood can be estimated by the oxygen content of the blood [1]. The blood oxygen content can be measured using a pulse oximeter. Pulse oximetry uses red and infrared light to distinguish hemoglobin and oxidized hemoglobin in the blood, and based on this, obtains oxygen saturation [4].

Another physical parameter that affects glucose measurement is the thickness of the earlobe tissue. This problem occurs when multiple people use a device, because the thickness of the earlobe may vary from person to person in this case. The thickness of the tissue determines the path length of the near-infrared light. The longer the path, the lower the light transmittance. The thickness of the earlobe tissue can be measured by green light with a higher skin attenuation rate.

Indium gallium arsenide photodiodes used to sense near-infrared spectral signals can also be used to sense other wavelengths (such as green, red, and infrared) because the spectral response of such diodes covers the wavelengths used above.

All of these variables are amplified, sampled, and processed in PSoC5LP and then transmitted via Bluetooth to an Android app. Figure 1 is a block diagram of the overall system flow.

Non-invasive blood glucose monitoring using near-infrared spectroscopy

Figure 1. System structure diagram

Induction and pretreatment

The indium gallium arsenide photodiode signal is sent to an amplifier to amplify the weak near infrared spectral signal. The attenuation of the red, infrared, and green signals does not affect, so no amplification is required. We can use an internal programmable gain amplifier (PGA) to amplify near-infrared spectral signals. A few millivolts of voltage change was recorded from the glucose change and amplified using a 1.024V reference voltage and a programmable amplifier with a gain of 50. The sensed signal is sampled using a single Δ∑ analog-to-digital converter along with an analog multiplexer. The near-infrared and green-light signals are sampled with an 18-bit resolution, and the red and infrared signals are sampled with a 16-bit resolution to increase the sampling rate and avoid signal aliasing caused by heart rate changes (see Figure 2).

Non-invasive blood glucose monitoring using near-infrared spectroscopy

Figure 2. External components and schematics of PsoC